Controlled Unclassified Information (CUI)
Information the government creates or possesses that law, regulation or policy requires to be safeguarded. In the DIB, CUI protection drives CMMC Level 2.12
Critical Digital Asset (CDA)
NRC term for a digital asset associated with safety, security or emergency preparedness functions at a nuclear plant that must be protected under 10 CFR 73.54.34
Cybersecurity Performance Goals (CPGs)
CISA's baseline set of cross-sector cybersecurity practices, with OT-specific goals, intended to reduce the most common risks.5
Data diode
A network device that physically allows data to travel in only one direction, typically enforced in hardware (for example, a transmitter with no receive path). Nothing, including attacks, can travel back the other way.64 Read the guide
Defense in depth
Layered, independent security controls so that a single failure does not compromise the system. Required by the NRC for nuclear power reactors.63
Distributed Control System (DCS)
A control system for a process within a single location (such as a refinery or power plant), with control distributed across multiple controllers under supervisory control.6
DMZ (industrial)
A buffer network between IT and OT that hosts the systems both sides need, so that no traffic passes directly between them.6
Historian
A database that records time-series process data. Historians are often replicated to the IT network so the business can use plant data without reaching into the control network.6
Human-Machine Interface (HMI)
The software and hardware that operators use to monitor and command a process.6
IEC 62443
The ISA/IEC series of standards for securing industrial automation and control systems, covering asset owners, system integrators and product suppliers.7
Industrial Control System (ICS)
The systems used to control industrial processes, including SCADA, distributed control systems and PLCs. ICS is a major subset of OT.68
Living off the land
Attacker use of legitimate built-in tools to avoid detection. CISA reported PRC state-sponsored actors using it to keep persistent access to U.S. critical infrastructure.9
NERC CIP
The North American Electric Reliability Corporation's Critical Infrastructure Protection standards, mandatory for the bulk electric system.10
Operational Technology (OT)
Programmable systems and devices that interact with the physical environment, or manage devices that do: industrial control systems, building automation, transportation and physical access systems.6
Programmable Logic Controller (PLC)
A ruggedized computer that reads inputs and drives outputs to control machinery. PLCs exposed to the internet with default credentials have been actively exploited.611
Purdue Model
A reference architecture that layers an industrial enterprise from physical process (Level 0) through control and supervisory levels up to enterprise IT, used to reason about segmentation between levels.6
Safety Instrumented System (SIS)
An independent control layer that takes a process to a safe state when conditions exceed limits. SIS integrity is a safety issue as much as a security one.6
SCADA
Supervisory Control and Data Acquisition: systems that monitor and control geographically dispersed assets such as pipelines, water networks and electric transmission.6
Security Level (SL)
IEC 62443's scale (SL 1 to SL 4) for the security capability a zone or component needs, based on the sophistication of the threats it must resist.7
Specialized Assets (CMMC)
CMMC scoping category that includes OT, IoT/IIoT, test equipment, government property and restricted information systems.12
Unidirectional gateway
A data diode combined with software that replicates servers or emulates devices on the destination side, so IT users can work with copies of OT data (historians, OPC servers, logs) without any path back into OT.6 Read the guide
Zones and conduits
The IEC 62443 approach to segmentation: group assets with common security requirements into zones, and control all communication between zones through defined conduits.7

Sources

  1. DoD CUI Registry
  2. 32 CFR Part 170, Cybersecurity Maturity Model Certification (CMMC) Program (eCFR)
  3. 10 CFR 73.54, Protection of digital computer and communication systems and networks (NRC)
  4. NRC Regulatory Guide 5.71, Rev. 1, Cyber Security Programs for Nuclear Power Reactors (Feb 2023)
  5. CISA, Cross-Sector Cybersecurity Performance Goals
  6. NIST SP 800-82 Rev. 3, Guide to Operational Technology (OT) Security (Sep 2023)
  7. ISA/IEC 62443 series of standards (ISA)
  8. CISA, Industrial Control Systems
  9. CISA Advisory AA24-038A, PRC state-sponsored actors (Volt Typhoon) in U.S. critical infrastructure
  10. NERC Reliability Standards (CIP family)
  11. CISA Advisory AA23-335A, IRGC-affiliated actors exploit PLCs in multiple sectors
  12. 32 CFR 170.19, CMMC scoping (eCFR)

Educational summary, not legal advice. Always confirm requirements against the current regulation and your contract.